Specifications of The Magnolias |
Centrally Air-conditioned Apartments |
Air-conditioning distribution shall be provided as per the standard layout of the apartment. Any changes in the same shall be to the allottees account |
RCC-Framed Structure |
Designed for Zone-5 as per IS Code No. IS-1893 (PART-I:2002) for earthquake resistance in structures |
|
Building entrance hall & main lift lobbies |
Combination of marble & granite |
Staircases/service lift lobby |
Terrazzo/Stone |
Walls |
Building facade |
Exterior paint |
Building entrance hall & main left lobbies |
Combination of marble/granite/ceramic cladding, plaster with acrylic emulsion paint/ wall covering. |
Staircases/service lifts |
Plaster with paint |
Apartment Areas : Floors |
All internal spaces in the Apartment, Decks, balconies |
Bare concrete/ IPS |
|
Door frames & internal door shutters |
No internal door frames and door shutters will be provided. |
Entrance doors (main entrance & service entrance doors) |
Commercial flush shutter/moulded skin doors with padlock
|
External doors & windows |
Aluminium frames and shutters. Fly mesh shutters limited to a portion of openable window area only. |
Hardware |
Brass/steel/powder coated aluminium/ anodized aluminium |
Bathrooms/kitchen |
Similar to other rooms. Will not be finished any further. |
Electrical : |
Only PVC conduits will be provided in the ceiling slabs up to drop points. Back-up power equivalent to about 20 KVA for typical Apartments, 30KVA for Pent houses & Duplex(s) per apartment considering 70% load factor, however, DG set capacity calculation shall take into account suitable overall diversity of 60% No light points, fixtures/switches will be provided. |
Plumbing /Sanitation |
Vertical stacks for water supply and drainage will be provided in the shafts with connecting points provided in the toilets /kitchen.
Limited copper piping for the connecting points only.
Internal distribution of water supply & drainage will be done by the customer according to the internal layouts at his own cost.
Water softening plant for the complex.
|
Fire Fighting/ Detection System: |
Fire fighting including sprinklers, and detection system shall be provided as per NBC norms Part IV SP-7 amendment No. 3, January 1997 |
Lifts |
Two numbers of passenger lifts and one service lift will be provided per tower, serving the basements as well. |
Club Facility |
Multipurpose room, swimming pool and change rooms, one squash court, two tennis courts, gymnasium, steam & sauna, pantry, pool table Laundromat, security control room, convenience shop & centralised services. (Facilities are indicative only, subject to change). |
General |
Car calling system or equivalent system. Water outlets and drainage for car washing facility within the complex. Facility for creche/ play school with playground.
Security system CCTV's / monitoring of limited portion of exteriors, periphery, entrance lobbies & the basement. |